Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Appl Immunohistochem Mol Morphol ; 22(8): 627-33, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21768875

RESUMO

Malignant peripheral nerve sheath tumors (MPNSTs) constitute <2% of soft tissue neoplasms in children and display a wide histologic spectrum including low-grade and epithelioid variants, although most are high-grade spindle cell sarcomas. Here, we describe an unusual case of a large retroperitoneal epithelioid MPNST diagnosed in a 7-year-old girl without family history or clinical features of neurofibromatosis type 1. The patient was treated by repeated surgical interventions, polychemotherapy, autologous stem cell transplantation, and irradiation therapy. Over the years, she developed multiple disseminated abdominal recurrences but is currently alive with very slowly progressing disseminated intra-abdominal disease 18 years from initial diagnosis. Histologically, the tumor was composed of medium-sized polygonal and ovoid-to-spindled cells set within a copious myxoid matrix with a prominent reticular and microcystic pattern reminiscent of the recently described reticular/microcystic schwannoma. Immunohistochemistry revealed strong and diffuse expression of S100, CD56, CD57, collagen IV, and neuron-specific enolase, with negativity for perineurial cell markers (claudin-1, epithelial membrane antigen, and glucose transporter-1) and other lineage-specific mesenchymal and epithelial antigens. This unusual variant of low-grade MPNST must be differentiated from a variety of other entities, in particular benign perineurioma, myxoid neurofibroma, and benign reticular/microcystic schwannoma. Confinement of the recurrent disease to the abdominal cavity emphasizes the necessity of primary curative wide excision of this highly recurring but nonmetastasizing low-grade neoplasm.


Assuntos
Neoplasias de Bainha Neural/patologia , Antígenos CD/imunologia , Criança , Feminino , Seguimentos , Humanos , Imuno-Histoquímica , Neoplasias de Bainha Neural/diagnóstico por imagem , Neoplasias de Bainha Neural/cirurgia , Ultrassonografia
2.
Invest Radiol ; 46(2): 116-23, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20856124

RESUMO

OBJECTIVES: computed tomography (CT) is considered the method of choice in thoracic imaging for a variety of indications. Sedation is usually necessary to enable CT and to avoid deterioration of image quality because of patient movement in small children. We evaluated a new, subsecond high-pitch scan mode (HPM), which obviates the need of sedation and to hold the breath. MATERIAL AND METHODS: a total of 60 patients were included in this study. 30 patients (mean age, 14 ± 17 month; range, 0-55 month) were examined with a dual source CT system in an HPM. Scan parameters were as follows: pitch = 3.0, 128 × 0.6 mm slice acquisition, 0.28 seconds gantry rotation time, ref. mAs adapted to the body weight (50-100 mAs) at 80 kV. Images were reconstructed with a slice thickness of 0.75 mm. None of the children was sedated for the CT examination and no breathing instructions were given. Image quality was assessed focusing on motion artifacts and delineation of the vascular structures and lung parenchyma. Thirty patients (mean age, 15 ± 17 month; range, 0-55 month) were examined under sedation on 2 different CT systems (10-slice CT, n = 18; 64-slice CT, n = 13 patients) in conventional pitch mode (CPM). Dose values were calculated from the dose length product provided in the patient protocol/dose reports, Monte Carlo simulations were performed to assess dose distribution for CPM and HPM. RESULTS: all scans were performed without complications. Image quality was superior with HPM, because of a significant reduction in motion artifacts, as compared to CPM with 10- and 64-slice CT. In the control group, artifacts were encountered at the level of the diaphragm (n = 30; 100%), the borders of the heart (n = 30; 100%), and the ribs (n = 20; 67%) and spine (n = 6; 20%), whereas motion artifacts were detected in the HPM-group only in 6 patients in the lung parenchyma next to the diaphragm or the heart (P < 0,001). Dose values were within the same range in the patient examinations (CPM, 1.9 ± 0.6 mSv; HPM, 1.9 ± 0.5 mSv; P = 0.95), although z-overscanning increased with the increase of detector width and pitch-value. CONCLUSION: high-pitch chest CT is a robust method to provide highest image quality making sedation or controlled ventilation for the examination of infants, small or uncooperative children unnecessary, whereas maintaining low radiation dose values.


Assuntos
Pediatria/métodos , Intensificação de Imagem Radiográfica/instrumentação , Radiografia Torácica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Fatores Etários , Proteção da Criança , Pré-Escolar , Relação Dose-Resposta à Radiação , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X/métodos
3.
Porto Alegre; Artmed; 2010. 363 p. ilus, tab.
Monografia em Português | Sec. Munic. Saúde SP, AHM-Acervo, CAMPOLIMPO-Acervo | ID: sms-2810

Assuntos
Humanos , Pediatria
4.
Porto Alegre; Artmed; 2010. 363 p. ilus, tab.
Monografia em Português | LILACS, AHM-Acervo, CAMPOLIMPO-Acervo | ID: lil-642081

Assuntos
Humanos , Pediatria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...